Air Handling Unit Cost

AHU pricing spans an order of magnitude for the same nominal airflow, because construction specification and access matter as much as duty. Here is what actually drives the number.

Air handling unit costs at a glance

Airflow duty
The starting point — but rarely the biggest variable
Construction spec
Standard vs corrosion-resistant vs hygienic — a large multiplier
Heat recovery
Plate, thermal wheel or run-around coil, and its efficiency
Access & craneage
Frequently the largest single line on a replacement
Controls
Small share of cost, large share of performance

Why quotes vary so much

Two AHUs with the same nominal airflow can differ several-fold in price. The gap is almost always in casing and coil specification, heat-recovery type and efficiency, and whether the unit is a standard product or built to a particular size and duty.

Why there is no simple price per m³/s

Airflow duty is where an AHU specification starts, and it is a poor predictor of cost on its own. Units built for the same nominal airflow routinely differ several-fold in price, and the reasons are worth understanding before you compare quotations. If you need the basics first, the explainer on what an air handling unit is covers the main components and filter classes.

Construction specification is the biggest single multiplier. A standard office AHU, a corrosion-resistant unit for a swimming pool hall, and a hygienic unit for a food or pharmaceutical application are genuinely different machines — different casing materials and treatments, different coil protection, different fixings, different internal finishes and drainage detailing. See pool AHUs for the clearest example of why this matters.

Heat recovery is the next. Whether the unit has recovery at all, and whether it uses a plate heat exchanger, a thermal wheel or a run-around coil, changes both cost and physical size. Recovery efficiency is a headline figure worth comparing directly between bidders, because on a system that runs continuously the difference compounds every hour of operation.

Standard product versus bespoke matters too. Manufacturers offer standard ranges at competitive prices; a unit built to fit a specific plant-room opening, or to hit an unusual duty, costs more and takes longer. On a replacement into an existing plant room, physical constraints frequently force the bespoke route — see air handling units.

Beyond the unit itself, fan and motor specification, filtration grade (higher grades cost more to buy and more to run, because finer filters mean higher pressure drop), attenuation where noise is a concern, and the controls package all move the total.

AHU prices: what is published

Bespoke air handling units are quote-only, so no honest page can give you an average. What can be shown is the list price of compact packaged heat-recovery units that UK sellers publish, which is where most of the small-commercial market sits.

UnitAirflow, m³/hHeat recoveryPrice ex VATSeller (source)
Daikin VAM800J800total-heat (enthalpy) core£1,992.08Orion Air Sales
Daikin VAM1000J1,000total-heat (enthalpy) core£3,018.19Orion Air Sales
Daikin VAM2000J2,000total-heat (enthalpy) core£3,909.28Orion Air Sales
Mitsubishi Electric Lossnay LGH-100RVX3-Eabout 1,000 (278 l/s)Lossnay paper total-heat core£2,008.00 to £2,153.41L&B Fans / NFAN
Mitsubishi Electric Lossnay LGH-200RVX3-Eabout 2,000 (556 l/s)Lossnay paper total-heat core£3,934.00 to £4,249.25L&B Fans / NFAN
Helios KWL EC 1400 D Pro1,771 (max)cross-counterflow plate£11,548.95Just Fans
Helios KWL EC 2600 S Pro3,195 (free-blowing)aluminium cross-counterflow£14,173.95Just Fans
S&P CADB/T-HE 54 ECOWATTup to about 5,400 (top of the 450–5,400 range)counterflow, up to 93%£13,103.44Just Fans

Prices as displayed on the sellers’ pages on 30 September 2026, equipment only, excluding VAT at 20% and excluding delivery, installation, ductwork or pipework, controls beyond those listed, and commissioning. Sellers change prices without notice; the links are the source. This is what is published, not an average and not a quote.

Read across the table and the pattern is clear: compact enthalpy-core units cluster at about £2 to £3 per m³/h, packaged units with filters and controls at roughly £4 to £6.50 per m³/h, and the same Lossnay model is listed 7% apart by two sellers. Installation, access, ductwork and controls are extra and, as the next section explains, often exceed the unit.

What the law requires of a new AHU

Since 1 January 2018 a new non-residential ventilation unit sold in Great Britain must meet the ecodesign requirements in Annex III of Regulation (EU) 1253/2014, retained in UK law. In plain terms:

  • a bidirectional unit (supply and extract) must have a heat recovery system with a thermal bypass;
  • the heat recovery must reach at least 73% thermal efficiency, or 68% for a run-around coil system;
  • the fans are capped by an internal specific fan power limit, for example 800 + E − F W per m³/s for units of 2 m³/s or more with plate or wheel recovery (E rewards efficiency above the minimum, F allows for fine filters), and 1,100 + E − 300 × qnom/2 − F below 2 m³/s;
  • every unit except a dual-use unit must have a multi-speed or variable-speed drive;
  • the unit must warn when filters need changing.

This matters for cost in two ways. A unit that does not meet these minimums cannot lawfully be placed on the market, so a quote for one is not a saving. And the same rules are why a compliant unit costs more to buy and less to run: the heat recovery and the fan limits are where the running-cost saving comes from.

The cost that is not the unit: getting it in

On replacement projects, installation regularly exceeds the price of the equipment, and the reason is almost always access.

Air handling units are large. Getting one into a plant room can require craneage, removal of louvres or roof sections, temporary structural work, or — quite commonly — splitting the unit into sections for transport and rebuilding it in place. Some plant rooms were built around their AHU, with no route large enough to remove it intact, and in those cases the existing unit may have to be cut up and removed in pieces.

The other installation lines: ductwork modifications where the new unit's connections differ; electrical supply and controls wiring; pipework for heating and cooling coils; structural support and anti-vibration mounting; commissioning and balancing, which on a ducted system is a substantial exercise in its own right and should be a priced deliverable with measured records; and builder's work and making good.

This is why an AHU quotation should always be read as a package. A low equipment price with installation excluded tells you very little.

Replace or refurbish?

Full replacement is not always the right answer, and refurbishment is frequently overlooked. Where the casing is structurally sound and the access problem is severe, replacing components in situ can deliver most of the benefit at a fraction of the disruption.

Refurbishment typically covers fan replacement — often the single highest-value item, since swapping an old belt-driven fan for a modern direct-drive EC fan can substantially cut energy use — plus coil replacement, filter section upgrades, damper and actuator renewal, controls replacement, and casing repairs with new insulation and panel seals.

Refurbishment makes most sense where the casing is sound, where access makes replacement very expensive, where the existing duty is still correct, and where the building can only tolerate short shutdowns. Replacement wins where the casing is corroded, where the duty has changed because the building's use has changed, where you want modern heat recovery that the old unit cannot accommodate, or where the unit is simply beyond economic repair.

A useful intermediate step: an upgrade to the controls and fans only is often the highest return per pound spent on an older AHU, because it addresses the running cost — which over the unit's life is the dominant number — without the capital and disruption of a full replacement.

Running cost: fans, filters and recovery

An AHU's lifetime cost is dominated by the energy its fans consume, and fan power rises sharply with resistance in the system. That makes three things unusually important.

Filter selection and maintenance. Filters are the largest single resistance in most systems, and a loaded filter costs energy every hour until it is changed. There is a genuine trade-off between filtration grade and running cost, and it should be a considered decision rather than an inherited default.

Fan type. Modern direct-drive EC fans avoid belt losses and modulate efficiently, which matters because ventilation systems, like cooling systems, spend most of their life below design duty.

Heat recovery efficiency. On a system moving large volumes of tempered air continuously, the difference between a mediocre and a good recovery efficiency is a large annual number. It is worth comparing this figure carefully rather than accepting that recovery is simply "included".

Then there is ductwork hygiene under TR19, which carries both indoor-air-quality and fire-safety dimensions and is a recurring cost — see SFG20 and maintenance and PPM.

Illustrative running cost, with the assumptions shown. A 2 m³/s unit running at the fan-power limit of 800 W per m³/s draws about 1.6 kW. Over 3,000 running hours a year that is 4,800 kWh. At the average price paid by a medium-sized non-domestic consumer (2,000 to 19,999 MWh a year) in the second quarter of 2026, 24.61p/kWh excluding the Climate Change Levy or 25.17p including it (DESNZ, table 3.4.1 and 3.4.2), fan power alone costs roughly £1,180 to £1,210 a year. A smaller business on the ‘small’ band paid 27.87p, so about £1,340. Your tariff, hours and filter resistance will differ; the point is that fan efficiency, not the purchase price, decides what an AHU costs over its life.

Frequently asked questions

How much does an air handling unit cost?

There is no reliable UK average, and the wide spans quoted online have no public source. Published, equipment-only prices for compact heat-recovery units ran from about £2,000 to £14,000 excluding VAT on 30 September 2026 (table above); bespoke units are quote-only. Airflow duty is only the starting point; construction specification, heat-recovery type and efficiency, filtration grade, controls, and whether the unit is standard or bespoke all move the price substantially, often several-fold for the same nominal airflow.

Why is installing an AHU more expensive than buying one?

Because access usually dominates. AHUs are large, and getting one into a plant room can require craneage, louvre or roof removal, temporary structural work, or splitting the unit into sections and rebuilding it in place. Add ductwork modifications, electrical and pipework connections, structural support, commissioning and balancing, and installation frequently exceeds the equipment cost.

Should I replace or refurbish my air handling unit?

Refurbish where the casing is structurally sound, access makes replacement very expensive, the duty is still correct and the building can only tolerate short shutdowns. Replace where the casing is corroded, the building's use has changed the required duty, or you want modern heat recovery the old unit cannot accommodate. Upgrading fans and controls alone is often the best return on an older unit.

What is the biggest running cost on an AHU?

Fan energy, and it rises sharply with system resistance. That makes filter selection and change frequency, fan type — modern direct-drive EC fans avoid belt losses and modulate well — and heat-recovery efficiency the three levers that matter most. Over the unit's life these normally exceed the purchase price considerably.

Do pool or food-industry AHUs cost more?

Substantially, because they are different machines. A pool hall AHU needs corrosion-resistant casing, coils, fasteners and drainage to survive warm chlorinated air, and hygienic units for food or pharmaceutical use have their own construction and finish requirements. This specification is the line most often trimmed when a project is over budget, and the consequence arrives years later.


See air handling units for capacity, construction and ductwork, pool AHUs for the specialist case, and the main cost guide for other systems. Or request a quote.

Sources and last checked

Every figure on this page was checked against the source listed on 30 September 2026.

How much is a new AHU?

It depends on whether it is a compact packaged unit or a bespoke one. Published UK list prices for compact heat-recovery units run from about £2,000 to £14,000 excluding VAT (table above, 30 September 2026); bespoke units are quote-only, and installation, access and controls frequently cost more than the unit itself.

How much does it cost to install a ventilation system in the UK?

There is no reliable national figure, because installation is driven by access, ductwork runs, electrical supply, controls integration and commissioning rather than by the unit. Ask for the unit, the installation and the controls as separate lines, and for the unit’s declared heat-recovery efficiency and specific fan power.

How much does a heat recovery unit cost?

Compact commercial heat-recovery units with published UK prices ran from £1,992 for an 800 m³/h enthalpy-core unit to £14,174 for a 3,195 m³/h plate unit, excluding VAT, on 30 September 2026 (table above). Larger units are quote-only. The price per m³/h falls as airflow rises and rises with filtration, controls and casing specification.

Get air handling unit quotes